Round metal object with type-N attachment.

The F-40-5 has a usable frequency range of 10 Hz – 50 MHz. Primary power currents of 1000 amperes DC – 400 Hz and 5000 amperes pulse will not alter the transfer impedance.

FCC F-40-5 Current Probe

Product Specifications

Product
Frequency
dBΩ (nominal)
ZtΩ (nominal)
Connector
Inner Diameter (mm.)
Outer Diameter (mm.)
Height (mm.)
Max Primary Current DC-400Hz
CW current (amperes)
Peak Pulse Current
Calibration Fixture
F-40-5 10 Hz - 50 MHz -20 0.1 Type-N 67 142 53 1000 60 5000 FCC-MPCF-2-67/142/53