The F-61D is for laboratory and field testing. This probe has a small outer
diameter, approximately 71 mm with an internal diameter of 32 mm. It can
operate up to 200 amperes of DC – 400 Hz.
Product |
Frequency |
dBΩ (nominal) |
ZtΩ (nominal) |
Connector |
Inner Diameter (mm.) |
Outer Diameter (mm.) |
Height (mm.) |
Max Primary Current DC-400Hz |
CW current (amperes) |
Peak Pulse Current |
Calibration Fixture |
---|---|---|---|---|---|---|---|---|---|---|---|
F-61D | 1 MHz - 1 GHz | 24 | 16 | Type-N | 32 | 71 | 19 | 200 | 10 | 50 | - |