Long metal device.

Electromagnetic frequently degrade the performance of electronic equipment by generating common mode currents on cables. RF immunity to these fields can be verified by injecting common-mode currents onto the cables of the equipment uder test. The F-203I-A-32mm EM Clamp is an high-efficiency, broadband clamp-on injection device that is used to test the immunity of electronic equipment when direct capacitive coupling technique is not possible nor appropriate. When the F-203I-A-32mm is used with the F-203I-A-CF3-32mm-150 and the F-203I-A-32mm-50 calibration fixtures, it fully complies with IEC61000-4-6 Edition 4.0.

FCC F-203I-A-32mm EM Injection Clamp

Product Specifications

Product
Coupling Aperture
Dimensions LxWxH (mm)
Input Power Rate
F-203I-A-32mm 32mm 610 x 105 x 190 10kHz - 1GHz: 100 watts CW (30 min)
Product specifications are subject to change without notice